Related Experiment Video
Updated: Dec 16, 2025

Establishment of a Novel Ex Vivo Lung Perfusion System for Rat Lungs After Circulatory Death
Published on: October 18, 2024
Optiflow vs Vapotherm as extended weaning mode from nasal continuous positive airway pressure in preterm infants ≤ 28
J Ramon Fernandez-Alvarez1,2, Liam Mahoney3, Rashmi Gandhi4
1Department of Neonatology, Royal Sussex County Hospital, Brighton and Sussex University Hospitals Trust, Brighton, UK.
Introduction:
Current evidence supports nasal continuous positive airway pressure (NCPAP) weaning. Heated humidified high-flow nasal cannula (HHFNC) reduces NCPAP time in infants less than 28 weeks gestational age (GA) without increasing morbidity. The aim of the study was to compare the two most frequently used HHFNC devices in weaning from NCPAP.
Methodology:
We performed a retrospective matched-pair case-control study of infants less than or equal to 28 GA born in a single tertiary neonatal center managed with Optiflow or Vapotherm after being weaned from NCPAP. Patients were matched for antenatal steroid doses, delivery mode, birth plurality, GA, birthweight, gender, surfactant doses, length of mechanical ventilation, and length of NCPAP. Outcome measures were duration of HHFNC, low-flow nasal cannula, nasal bridge lesions, pneumothorax, bronchopulmonary dysplasia, postnatal steroids, necrotizing enterocolitis, sepsis, intraventricular hemorrhage, retinopathy of prematurity, length of stay, discharge weight, and mortality. Results were displayed as median (interquartile range) or ratio (percentage). Statistical analysis was performed using Mann-Whitney U and χ2 tests.
Results:
70 patients were recruited retrospectively. Thirty-five infants were weaned from NCPAP to Optiflow and 35 infants to Vapotherm with gestational ages and birthweights of 27 GA (26-27) and 1010 g (835-1165) and 27 GA (26-28) and 960 g (788-1191), respectively. There was no statistically significant difference in any outcome measure. Infants managed with Vapotherm required a not statistically significant shorter length of time on HHFNC and low-flow nasal cannula.
Conclusions:
Optiflow and Vapotherm seem to be equally effective and safe for weaning from NCPAP. However, infants weaned to Vapotherm appear to spend less time on non-invasive respiratory support.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...