Automated Calibration System for Digital Multimeters Not Equipped with a Communication Interface.

Grzegorz Grzeczka1, Maciej Klebba1

  • 1Faculty of Mechanical and Electrical Engineering, Polish Naval Academy, 81-127 Gdynia, Poland.

Sensors (Basel, Switzerland)
|July 3, 2020
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

593
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
593
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

356
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
356
Galvanometer01:25

Galvanometer

2.6K
Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of  two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.6K
Potentiometer01:30

Potentiometer

1.6K
Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
1.6K
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

3.9K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
3.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Underwater Magnetic Sensors Network.

Sensors (Basel, Switzerland)·2025
Same author

Time Constant as the Main Component to Optimize the Resistance Temperature Sensors' Calibration Process.

Sensors (Basel, Switzerland)·2024
Same author

Application of Multi-Criteria Optimization Methods in the Calibration Process of Digital Measuring Instruments.

Sensors (Basel, Switzerland)·2023
See all related articles

This study presents practical solutions for automatic calibration of digital multimeters using specialized software. It details the structure and implementation of automated calibration systems for enhanced measurement accuracy.

Area of Science:

  • Metrology
  • Electrical Engineering
  • Measurement Science

Background:

  • Accurate calibration of digital multimeters (DMMs) is crucial for reliable electrical measurements.
  • Traditional manual calibration methods can be time-consuming and prone to errors.

Purpose of the Study:

  • To present the concept and practical solutions for automated calibration stations for DMMs.
  • To describe the general structure, application scheme, and technical implementation of these automated systems.

Main Methods:

  • Development of software for automatic calibration of DMMs.
  • Design and implementation of a general measuring system architecture.
  • Integration of hardware and software for automated calibration stations.
Keywords:
automationcalibrationdot recognition

More Related Videos

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

7.2K
A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
08:27

A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine

Published on: December 6, 2024

554

Related Experiment Videos

Last Updated: Dec 16, 2025

Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
10:00

Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels

Published on: June 2, 2020

22.2K
Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

7.2K
A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
08:27

A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine

Published on: December 6, 2024

554

Main Results:

  • Demonstration of a functional automated calibration system for DMMs.
  • Presentation of a software solution enabling efficient and accurate calibration.
  • Detailed technical specifications for the measuring stations.

Conclusions:

  • Automated calibration stations offer a viable and efficient solution for DMM calibration.
  • The presented software and system design facilitate improved measurement accuracy and reduced calibration time.