A new method for identification of outliers in immunogenicity assay cut point data
Jianchun Zhang1, Rosalin Hgp Arends1, Robert J Kubiak1
1AstraZeneca PLC.
Abstract:
The cut point is an important parameter for immunogenicity assay validation and critical to immunogenicity assessment in clinical trials. FDA (2019) recommends using a statistical approach to derive cut point, with an appropriate outlier removal procedure. In general, the industry follows the methods described in Shankar et al. (2008) and Zhang et al. (2013) among others to determine cut point. Outlier removal is a necessary step during the cut point determination exercise to reduce potential false negative classifications. However, the widely used statistical outlier removal method, namely, Tukey's box-plot method (1.5 times inter-quartile range, IQR), is often found to be overly conservative in the sense that it removes too many "outliers". Tukey's box-plot method can be used to flag potential outliers for further investigation, however, it is not a hypothesis testing based statistical method. Removing these suspected "outliers" will lead to lower cut point which might confound immunogenicity assessment due to the presence of many low false positives. Besides, the very nature of assay analytical variability has a non-negligible adverse impact on the reliability of ADA classification in terms of false positive and false negative, demanding as large as possible contribution from biological variability relative to analytical variability. A new outlier removal procedure, which takes into account the relative magnitude between biological variability and analytical variability within the sample population, is proposed and statistically justified. After sequential removal of analytical and biological outliers, a 5% false positive rate and 1% false positive rate in screening and confirmatory assays, respectively, are still targeted without increasing potential false negatives. Internal data shows that this practice has minimal impact on assay sensitivity and has the advantage of selecting true positive samples. It is shown that the new procedure is more appropriate for cut point determination.
More Related Videos
13:41Use of Interferon-γ Enzyme-linked Immunospot Assay to Characterize Novel T-cell Epitopes of Human Papillomavirus
Published on: March 8, 2012
04:58Author Spotlight: Investigating the Role of Repetitive DNA Misregulation in Cancer Initiation and Immunotherapy Resistance
Published on: December 13, 2024
Related Concept Videos
Quantifying and Rejecting Outliers: The Grubbs Test
Detection of Gross Error: The Q Test
What Are Outliers?
The z score is used to find outliers or unusual values. It should be noted that any values beyond -2 and +2 are...
Outliers and Influential Points
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...