Related Experiment Video
Updated: Dec 16, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Built-in software in children on long-term ventilation in real life practice
Alessandro Onofri1, Martino Pavone1, Simone De Santis2
1Pediatric Pulmonology & Respiratory Intermediate Care Unit, Sleep and Long Term Ventilation Unit, Academic Department of Pediatrics (DPUO), Pediatric Hospital "Bambino Gesù" Research Institute, Rome, Italy.
Abstract:
Information gathered with built-in software (BIS) on new ventilators allow clinicians to access long-term noninvasive ventilation (LTNIV) data. Nevertheless, few evidence are available in literature that highlight potential strengths and disadvantages of using BIS in pediatrics. We aim to evaluate the use of BIS in a cohort of 90 children on LTNIV in our unit, focusing mainly on adherence, air leaks, and residual sleep events. We found that caregivers' perception of ventilator use is independent from objective adherence (P = .137). Furthermore, we failed to find any predictors of adherence. As regards air leaks, we found that pre-scholars' (0-6 years old) total air leaks are lower than teenagers' (more than 12 years old) (P < .05). Multiple regressive analysis showed that age at the beginning of therapy is a predictor of total air leaks: prescholars are associated with lower values (P < .05), while scholars (6-12 years old) are associated with higher values (P < .05). Finally, we explored the validity of BIS automatic scoring of sleep events (AHIBIS ) as compared with the manual scoring of polygraphy (AHIPG ). AHIBIS is within a range of 3.98 from AHIPG in 95% of cases, with a 64% of sensitivity and a 67% of specificity in identifying a pathological state. The disagreement between the two methods seems to increase for high AHI values. In conclusion, data gathered by BIS are a useful support tool for the clinician in assessing the course of LTNIV. However, clinicians must be aware of the several limitations of built-in software, especially in pediatrics.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

