Pneumonia Detection in Chest X-Ray Dose-Equivalent CT: Impact of Dose Reduction on Detectability by Artificial
Moritz Schwyzer1, Katharina Martini2, Stephan Skawran2
1Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, CH-8091 Zurich, Switzerland; School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania; University of Zurich, Zurich, Switzerland.
Rationale And Objectives:
There has been a significant increase of immunocompromised patients in recent years due to new treatment modalities for previously fatal diseases. This comes at the cost of an elevated risk for infectious diseases, most notably pathogens affecting the respiratory tract. Because early diagnosis and treatment of pneumonia can help reducing morbidity and mortality, we assessed the performance of a deep neural network in the detection of pulmonary infection in chest X-ray dose-equivalent computed tomography (CT).
Materials And Methods:
The 100 patients included in this retrospective study were referred to our department for suspicion of pulmonary infection and/or follow-up of known pulmonary nodules. Every patient was scanned with a standard dose (1.43 ± 0.54 mSv) and a 20 times dose-reduced (0.07 ± 0.03 mSv) CT protocol. We trained a deep neural network to perform binary classification (pulmonary consolidation present or not) and assessed diagnostic performance on both standard dose and reduced dose CT images.
Results:
The areas under the curve of the deep learning algorithm for the standard dose CT was 0.923 (confidence interval [CI] 95%: 0.905-0.941) and significantly higher than the areas under the curve (0.881, CI 95%: 0.859-0.903) of the reduced dose CT (p = 0.001). Sensitivity and specificity of the standard dose CT was 82.9% and 93.8%, and of the reduced dose CT 71.0% and 93.3%.
Conclusion:
Pneumonia detection with X-ray dose-equivalent CT using artificial intelligence is feasible and may contribute to a more robust and reproducible diagnostic performance. Dose reduction lowered the performance of the deep neural network, which calls for optimization and adaption of CT protocols when using AI algorithms at reduced doses.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...