Tracking the motion of intracardiac structures aids the development of future leadless pacing systems
Orod Razeghi1, Marina Strocchi1, Angela Lee1
1Department of Biomedical Engineering, Cardiac Electromechanics Research Group, School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK.
Background:
Leadless pacemakers preclude the need for permanent leads to pace endocardium. However, it is yet to be determined whether a leadless pacemaker of a similar design to those manufactured for the right ventricle (RV) fits within the left ventricle (LV), without interfering with intracardiac structures.
Methods:
Cardiac computed tomography scans were obtained from 30 patients indicated for cardiac resynchronisation therapy upgrade. The mitral valve annulus, chordae tendineae, papillary muscles and LV endocardial wall were marked in the end-diastolic frame. Intracardiac structures motions were tracked through the cardiac cycle. Two pacemaker designs similar to commercially manufactured leadless systems (Abbott's Nanostim LCP and Medtronic's Micra TPS) as well as theoretical designs with calculated optimal dimensions were evaluated. Pacemakers were virtually placed across the LV endocardial surface and collisions between them and intracardiac structures were detected throughout the cycle.
Results:
Probability maps of LV intracardiac structures collisions on a 16-segment AHA model indicated possible placement for the Nanostim LCP, Micra TPS, and theoretical designs. Thresholding these maps at a 20% chance of collision revealed only about 36% of the endocardial surface remained collision-free with the deployment of Micra TPS design. The same threshold left no collision-free surface in the case of the Nanostim LCP. To reach at least half of the LV endocardium, the volume of Micra TPS, which is the smaller design, needed to be decreased by 41%.
Conclusion:
Due to the presence of intracardiac structures, placement of leadless pacemakers with dimensions similar to commercially manufactured RV systems would be limited to apical regions.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...