Related Experiment Video
Updated: Dec 15, 2025

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Diagnosing Hepatocellular Carcinoma:
Hang Zhou1, Chao Zhang1, Linyao Du2
1Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, Hangzhou, China.
Objectives:
To determine the diagnostic performance and inter-reader agreement of the contrast-enhanced ultrasound liver imaging reporting and data system (CEUS-LI-RADS) for diagnosing hepatocellular carcinoma (HCC) in high-risk patients.
Methods:
In this prospective study, CEUS-LI-RADS categories (LR-5 for predicting HCC) were assigned by six blinded readers and compared to the definitive HCC diagnosis in patients with liver cirrhosis per the 2017 China Liver Cancer Guidelines (CLCG). CEUS features were recorded in 96 patients with 96 histology-proven lesions. The diagnostic performance of LR-5 was described by the sensitivity, specificity and accuracy. Multi-reader agreement was assessed by using intraclass correlation coefficients (ICC).
Results:
In cirrhotic patients, the specificity of LR-5 (range: 92.7-100.0 %) was statistically higher than that of CLCG for each reader (range: 28.6-64.3 %). However, the sensitivity (range: 38.6-63.6 %) and accuracy (range: 53.4-70.7 %) were statistically lower in CEUS-LIRADS than in CLCG (sensitivity range: 88.6-100.0 %; accuracy range: 77.6-86.2 %). Only fair to moderate inter-reader agreement was achieved for the CEUS-LI-RADS category (ICC = 0.595) and washout appearance (ICC range: 0.338 to 0.555). Neither nodule-in-nodule nor mosaic architecture was observed more often in HCC (all P > 0.05), with poor inter-reader consistency for both (both ICC < 0.20).
Conclusion:
CEUS-LI-RADS category 5 has a high specificity but a low accuracy for identifying HCC in high-risk patients. Inter-reader agreement is not satisfactory concerning CEUS-LIRADS category and washout appearance. Moreover, the clinical value of ancillary features favoring HCC is quite limited.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:03Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography