Related Experiment Video
Updated: Dec 15, 2025

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Mutual comparative analysis: a new topography-guided custom ablation protocol referencing subjective refraction to
Kaiwei Cao1, Lina Liu2, Tao Zhang2
1People's Liberation Army (PLA), No.1441 FengJu Ring Road, Jinniu District, Chengdu, 610081 China.
Background:
Several planning algorithms have been developed for topography-guided custom ablation treatment (T-CAT), but each has its own deficiencies. The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis (MCA) informed by manifest refraction and corneal topographic data and the patient's subjective perception in correcting ametropia.
Methods:
This retrospective review included patients with significant preoperative differences in the power or axis of astigmatism according to the manifest refraction and corneal topographic data (power > 0.75 D and/or axis > 10°). T-CAT planning was designed using MCA. Follow-ups were conducted for at least 6 months.
Results:
Seventy-nine patients (121 eyes) were included. The mean preoperative deviation in the astigmatic power and axis were 0.72 ± 0.43 D and 20.18 ± 23.68°, respectively. The average oculus residual astigmatism (ORA) was 0.81 ± 0.32 D (range: 0.08-1.66 D). Six months postoperatively, the mean spherical equivalent refraction was 0.04 ± 0.42 D, and the mean cylinder was - 0.27 ± 0.24 D. The mean efficacy and safety indices were 1.10 and 1.15, respectively. The uncorrected distance visual acuity in 92% of the eyes was the same or better than the corrected distance visual acuity. The angle of error was ±5° in 61% of eyes and ± 15° in 84% of eyes. Residual astigmatism was ≤0.5 D in 91% of eyes. Optical quality and photopic contrast sensitivity did not change significantly (p > 0.05), and the scotopic contrast sensitivity decreased at 3, 6, and 12 cpd (p < 0.05). The vertical coma and horizontal coma of the anterior corneal surface significantly decreased postoperatively but increased during follow-up.
Conclusions:
The MCA demonstrated safety, efficacy, accuracy, predictability, and stability and can be used as a complementary and feasible method for T-CAT.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011