Related Experiment Video
Updated: Dec 15, 2025

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Analysis of impurities in pharmaceuticals by LC-MS with cold electron ionization
Svetlana Tsizin1, Alexander B Fialkov1, Aviv Amirav1
1School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel.
Abstract:
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography-mass spectrometry (LC-MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC-MS with supersonic molecular beams (SMB). The EI-LC-MS-SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI-LC-MS-SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal-to-noise ratio of over 10 000 for the API and almost uniform response.
More Related Videos
09:09Preparation of Human Tissues Embedded in Optimal Cutting Temperature Compound for Mass Spectrometry Analysis
Published on: April 27, 2021
09:24Standardized Identification of Compound Structure in Tibetan Medicine Using Ion Trap Mass Spectrometry and Multiple-Stage Fragmentation Analysis
Published on: March 17, 2023
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion-Exchange Chromatography
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...