Related Experiment Video
Updated: Dec 14, 2025

Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Ecotoxicity Evaluation of Pure Peracetic Acid (PAA) after Eliminating Hydrogen Peroxide from Commercial PAA
Ravi Kumar Chhetri1, Silvia Di Gaetano2, Andrea Turolla3
1Department of Environmental Engineering, Technical University of Denmark, 2800 Kongens Lyngby, Denmark.
Abstract:
In recent years, peracetic acid (PAA) has gained a lot of attention as an alternative disinfectant to chlorine-based disinfectants in the water industry. Commercial PAA solutions contain both PAA and hydrogen peroxide (HP), and the degradation of HP is slower than PAA when it is used for disinfection. All previous toxicity studies have been based on commercial PAA, and variance in toxicity values have been observed due to different PAA:HP ratios. In this study, the ecotoxicity of pure PAA was studied, eliminating HP from the commercial PAA mixture using potassium permanganate. Ecotoxicity data were obtained by conducting a battery of ecotoxicity tests: bioassays using Vibrio fischeri (V. fischeri), Daphnia magna (D. magna), and Pseudokirchneriella subcapitata (P. subcapitata). The effect concentration (EC50) of pure PAA was 0.84 (a 95% confidence interval of 0.78-0.91) mg/L for V. fischeri and 2.46 (2.35-2.58) mg/L for P. subcapitata, whereas the lethal concentration (LC50) was 0.74 (0.55-0.91) mg/L for D. magna. Compared to this, our previous study found that the EC50 values of commercial PAA towards V. fischeri and P. subcapitata were 0.42 (0.41-0.44) and 1.38 (0.96-1.99) mg/L, respectively, which were lower than pure PAA, whilst the LC50 for D. magna was 0.78 (0.58-0.95) mg/L. These results showed that pure PAA was less toxic to the most commonly used aquatic species for toxicity tests compared to commercial PAA, except for D. magna.
More Related Videos
16:33Methods for Facilitating Microbial Growth on Pulp Mill Waste Streams and Characterization of the Biodegradation Potential of Cultured Microbes
Published on: December 12, 2013
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
Autoxidation of Ethers to Peroxides and Hydroperoxides
Esters to Carboxylic Acids: Acid-Catalyzed Hydrolysis
During hydrolysis, the ester is first activated towards nucleophilic attack through the protonation of the carboxyl oxygen atom by the acid catalyst. The protonation makes the ester carbonyl carbon more electrophilic. In the next step, water acts as a nucleophile and adds to the...
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
Polyprotic Acids
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as: