Interactions between gold, thiol and As(iii) for colorimetric sensing

Junling Duan1, Biwu Liu, Juewen Liu

  • 1College of Chemistry and Material Science, Shandong Agricultural University, Tai'an, Shandong 271018, P.R. China.

The Analyst
|July 18, 2020
PubMed
Summary

Arsenic(iii) detection using gold nanoparticles (AuNPs) may involve ligand displacement, not crosslinking. High arsenic concentrations and irreversible color changes suggest adsorption onto AuNPs is key, not ligand crosslinking.

Related Concept Videos

Preparation and Reactions of Thiols02:33

Preparation and Reactions of Thiols

Thiols are prepared using the hydrosulfide anion as a nucleophile in a nucleophilic substitution reaction with alkyl halides. For instance, bromobutane reacts with sodium hydrosulfide to give butanethiol.
7.3K
Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
5.1K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
541
Complexometric Titration: Overview00:39

Complexometric Titration: Overview

Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free...
10.5K