Improved HPLC Conditions to Determine Eumelanin and Pheomelanin Contents in Biological Samples Using an Ion Pair
Shosuke Ito1, Sandra Del Bino2, Tomohisa Hirobe3
1Department of Chemistry, Fujita Health University School of Medical Sciences, Toyoake 470-1192, Japan.
Abstract:
Alkaline hydrogen peroxide oxidation (AHPO) of eumelanin and pheomelanin, two major classes of melanin pigments, affords pyrrole-2,3,5-tricarboxylic acid (PTCA), pyrrole-2,3-dicarboxylic acid (PDCA) and pyrrole-2,3,4,5-tetracarboxylic acid (PTeCA) from eumelanin and thiazole-2,4,5-tricarboxylic acid (TTCA) and thiazole-4,5-dicarboxylic acid (TDCA) from pheomelanin. Quantification of these five markers by HPLC provides useful information on the quantity and structural diversity of melanins in various biological samples. HPLC analysis of these markers using the original method of 0.1 M potassium phosphate buffer (pH 2.1):methanol = 99:1 (85:15 for PTeCA) on a reversed-phase column had some problems, including the short lifetime of the column and, except for the major eumelanin marker PTCA, other markers were occasionally overlapped by interfering peaks in samples containing only trace levels of these markers. These problems can be overcome by the addition of an ion pair reagent for anions, such as tetra-n-butylammonium bromide (1 mM), to retard the elution of di-, tri- and tetra-carboxylic acids. The methanol concentration was increased to 17% (30% for PTeCA) and the linearity, reproducibility, and recovery of the markers with this improved method is good to excellent. This improved HPLC method was compared to the original method using synthetic melanins, mouse hair, human hair, and human epidermal samples. In addition to PTCA, TTCA, a major marker for pheomelanin, showed excellent correlations between both HPLC methods. The other markers showed an attenuation of the interfering peaks with the improved method. We recommend this improved HPLC method for the quantitative analysis of melanin markers following AHPO because of its simplicity, accuracy, and reproducibility.
More Related Videos
05:52Author Spotlight: Enhanced Histone PTM Isomer Identification Through LC-TIMS-ToF MS/MS and PASEF
Published on: January 12, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process