Related Experiment Video
Updated: Dec 14, 2025

Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Published on: October 12, 2015
Electrochemical Nanoaptasensor for Continuous Monitoring of ATP Fluctuation at Subcellular Level
Jingyi Zheng1, Xiaoxia Li1, Ke Wang2
1School of Chemistry and Chemical Engineering, Yan'an University, Yan'an 716000, P. R. China.
Abstract:
Monitoring the fluctuation of adenosine 5'-triphosphate (ATP) at the subcellular level is important for the study of cell energy metabolism. Herein, we fabricated an electrochemical nanoaptasensor for continuously monitoring ATP fluctuation at the subcellular level. A gold nanoelectrode with a diameter of 120 nm was fabricated, and ferrocene (Fc)-labeled anti-ATP aptamer was self-assembled onto the nanoelectrode surface to form a nanoaptasensor. In the presence of ATP, the ferrocene-labeled anti-ATP aptamer bound with two ATP units to form an ATP-aptamer conjugation, resulting in the close proximity of Fc to the nanoelectrode surface and then an increase of oxidation current of Fc. ATP can be detected with a detection limit of 26 μM within 2 min. Cell viability assays indicated that the nanoaptasensor was biocompatible with negligible biological effects. By taking advantage of the good biocompatibility of the nanoaptasensor, ATP fluctuation at the subcellular level was monitored under glucose starvation and Ca2+ induction. This work demonstrates that the nanoaptasensor is a useful tool for investigating ATP-relevant biological processes via the electrochemical method.
More Related Videos
11:20Imaging of Intracellular ATP in Organotypic Tissue Slices of the Mouse Brain using the FRET-based Sensor ATeam1.03YEMK
Published on: December 19, 2019
10:28A Semi-High-Throughput Adaptation of the NADH-Coupled ATPase Assay for Screening Small Molecule Inhibitors
Published on: August 17, 2019
Related Concept Videos
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
ATP Synthase: Structure
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Hydrolysis of ATP
If one phosphate group is removed, a molecule of ADP—adenosine diphosphate—remains, along with inorganic phosphate. ADP can be further hydrolyzed to AMP—adenosine...