Related Experiment Video
Updated: Dec 13, 2025

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Utilization of the hysteresis phenomenon for chiral high-performance liquid chromatographic method selection in polar
Simon Horváth1, Zsuzsanna Eke2, Gábor Németh3
1György Hevesy Doctoral School of Chemistry, Eötvös Loránd University, Pázmány Péter stny. 1/A, H-1117 Budapest, Hungary; Drug Substance Development Division, Egis Pharmaceuticals PLC, P. O. Box 100, H-1475 Budapest, Hungary.
Abstract:
Polysaccharide-based chiral stationary phases (CSPs) are outstandingly suitable to play a key role in chiral HPLC method selection strategies, since they provide high success rates. One reason for this ability is that they adopt a diversity of higher order structures in various eluents, resulting in versatile chiral environments. A potential to extend this versatility further was expected and examined in the present study, based on the recently discovered hysteretic behavior of a widely used chiral selector (CS), amylose tris(3,5-dimethylphenylcarbamate). The hindered transitions of its structure, which are behind the history dependence of its separation ability, were used as a tool to identify distinct states of the chiral selector in order to exploit an extended selectivity space. The identification was carried out using a single diagnostic compound, as opposed to the common approach where testing a library of compounds is required. Eluent mixtures consisting of 2-propanol and either methanol or ethanol were scrutinized in terms of stability and robustness of the observed retentions. The solvent mixtures that were eligible for practical application in these respects were used to construct a screening sequence, including identical compositions combined with different column pretreatment. The gain achievable by using the proposed sequence was then evaluated using 15 enantiomer pairs with focus on resolution, enantiomer elution order and chemoselectivity.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography

