Related Experiment Video
Updated: Dec 13, 2025

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Assessment of the conventional radial artery with optical coherent tomography after the snuffbox approach
Yongcheol Kim1,2, Sang Yeub Lee3,4, Dae In Lee5
1Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine and Cardiovascular Center, Yongin Severance Hospital, Yongin, Korea, Republic Of.
Background:
This study aimed to evaluate acute injuries of the radial artery (RA) using optical coherence tomography (OCT) in patients who underwent coronary intervention via the snuffbox approach.
Methods:
Forty-six patients, who underwent coronary intervention and assessment of the conventional RA using OCT via the snuffbox approach, were enrolled from two university hospitals between August 2018 and August 2019.
Results:
The mean age of the patients was 65.1 years. In this study population, 6-French (Fr) sheaths were used. The mean diameter of the conventional RA was 2.89 ± 0.33 mm, and the mean lumen area of the conventional RA was 6.68 ± 1.56 mm2. Acute injuries of the conventional RA, after the snuffbox approach, were observed in 5 (10.9%) patients. Intimal tear was observed in the RA in 1 (2.2%) case. Intraluminal thrombi, without vessel injuries, were detected in the RA in 4 (8.7%) cases. However, medial dissection was not observed in the OCT analysis.
Conclusions:
This retrospective OCT-based study showed that the diameter of the conventional RA was 2.89 mm and acute vessel injury of the conventional RA was rare in patients who underwent coronary intervention via the snuffbox approach.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...