100 MHz bandwidth planar laser-generated ultrasound source for hydrophone calibration
Srinath Rajagopal1, Ben T Cox2
1Ultrasound and Underwater Acoustics Group, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, UK.
Abstract:
High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultrasonic fields often contain energy at higher frequencies, e.g., generated through nonlinear propagation of high-amplitude ultrasound used for therapeutic applications, and the increasing use of higher frequencies in imaging. Therefore, there is a need for calibrations up to at least 100 MHz, to allow ultrasonic fields to be accurately characterized, and the risk of harmful bioeffects to be properly assessed. Currently, sets of focused piezoelectric transducers are used to meet the pressure amplitude and bandwidth requirements of Primary Standard calibration facilities. However, when the frequency is high enough such that the size of the ultrasound focus becomes less than the hydrophone element's diameter, the uncertainty due to spatial averaging becomes significant, and can be as high as 20% at 100 MHz. As an alternate to piezoelectric transducers, a laser-generated ultrasound calibration source was designed, fabricated, and characterized. The source consists of an optically absorbing carbon-polymer nanocomposite excited by a large-diameter 1064 nm laser pulse of 2.6 ns duration. Peak pressure amplitudes of several Mega-Pascal were readily achievable, and the signal contained measurable frequency components up to 100 MHz. The variation in the pressure amplitudes was less than 2% from its mean over a three-hour test period. The ultrasound beam was sufficiently broad that the uncertainties due to spatial averaging were negligible.
More Related Videos
08:19Induction of Microstreaming by Nonspherical Bubble Oscillations in an Acoustic Levitation System
Published on: May 9, 2021
12:00Synthesis of Gold Nanoparticle Integrated Photo-responsive Liposomes and Measurement of Their Microbubble Cavitation upon Pulse Laser Excitation
Published on: February 24, 2016