Related Experiment Video
Updated: Dec 13, 2025

Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Derivation of Breathing Metrics From a Photoplethysmogram at Rest: Machine Learning Methodology
Joseph Prinable1, Peter Jones1, David Boland1
1School of Electrical and Information Engineering, The University of Sydney, Darlington, Australia.
Background:
There has been a recent increased interest in monitoring health using wearable sensor technologies; however, few have focused on breathing. The ability to monitor breathing metrics may have indications both for general health as well as respiratory conditions such as asthma, where long-term monitoring of lung function has shown promising utility.
Objective:
In this paper, we explore a long short-term memory (LSTM) architecture and predict measures of interbreath intervals, respiratory rate, and the inspiration-expiration ratio from a photoplethysmogram signal. This serves as a proof-of-concept study of the applicability of a machine learning architecture to the derivation of respiratory metrics.
Methods:
A pulse oximeter was mounted to the left index finger of 9 healthy subjects who breathed at controlled respiratory rates. A respiratory band was used to collect a reference signal as a comparison.
Results:
Over a 40-second window, the LSTM model predicted a respiratory waveform through which breathing metrics could be derived with a bias value and 95% CI. Metrics included inspiration time (-0.16 seconds, -1.64 to 1.31 seconds), expiration time (0.09 seconds, -1.35 to 1.53 seconds), respiratory rate (0.12 breaths per minute, -2.13 to 2.37 breaths per minute), interbreath intervals (-0.07 seconds, -1.75 to 1.61 seconds), and the inspiration-expiration ratio (0.09, -0.66 to 0.84).
Conclusions:
A trained LSTM model shows acceptable accuracy for deriving breathing metrics and could be useful for long-term breathing monitoring in health. Its utility in respiratory disease (eg, asthma) warrants further investigation.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Volumes and Capacities I
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...