Related Experiment Video
Updated: Dec 13, 2025

Measurement of Antibody Effects on Cellular Function of Isolated Cardiomyocytes
Published on: March 8, 2013
A functional cell-based bioassay for assessing adrenergic autoantibody activity in postural tachycardia syndrome
Thariq Badiudeen1, Elizabeth A Forsythe2, Graham Bennett1
1Department of Cardiac Sciences, Libin Cardiovascular Institute of Alberta, University of Calgary, Calgary, T2N 4N1, Canada.
Background:
Activating autoantibodies (AAb) to adrenergic receptors (AR) have previously been reported in patients with postural tachycardia syndrome (POTS). These AAb may contribute to a final common pathway for overlapping disease processes, reflecting a possible autoimmune contribution to POTS pathophysiology. In prior studies, measurement of AAb activity was inferred from costly, low-throughput, and laborious physiological assays. In the present study, we developed and validated an alternative cell-based bioassay for measuring AAb activity in serum by means of pre-treatment with monoamine oxidase (MAO).
Methods:
A total of 37 POTS patients and 61 sex-matched healthy control participants were included. Serum was pre-treated with MAO to remove endogenous catecholamines that could falsely inflate AR activation by AAb. A receptor-transfected cell-based bioassay was used to detect presence of α1AR-AAb and β1AR-AAb in serum.
Results:
MAO effectively degraded catecholamines as demonstrated by suppression of norepinephrine-induced α1AR activation in POTS (6.4 ± 0.7 vs. 5.5 ± 0.9; P = 0.044) and in controls (4.1 ± 0.5 vs. 3.9 ± 0.6; P = 0.001). Mean activity values were greater in the POTS vs. Controls for α1AR-AAb (6.2 ± 1.2 vs. 5.3 ± 1.0; P < 0.001) and β1AR-AAb (5.7 ± 1.8 vs. 4.1 ± 0.9; P < 0.001). Compared to controls, more POTS patients were positive for α1AR-AAb activity (22% vs 4%; P = 0.007) and β1AR-AAb activity (52% vs. 2%; P < 0.001).
Conclusions:
The co-presence of norepinephrine in serum samples can artifactually elevate α1AR and β1AR activity, which can be avoided by serum pre-treatment with MAO. Using this novel bioassay, we show that POTS patients have increased α1AR-AAb and β1AR-AAb activity compared to healthy controls in the largest POTS cohort reported to-date.
Related Concept Videos
Sympathetic Signaling
Sympathetic preganglionic fibers release the neurotransmitter acetylcholine (ACh) onto the ganglionic neurons in the...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.