Related Experiment Video
Updated: Dec 13, 2025

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Non-Contact Assessment of Peripheral Artery Haemodynamics Using Infrared Video Thermography
Abstract:
Skin temperature has long been used as a natural indicator of vascular diseases in the extremities. Considerable correlation between oscillations in skin surface temperature and oscillations of skin blood flow has previously been demonstrated. We hypothesised that the impairment of blood flow in stenotic (subcutaneous) peripheral arteries would influence cutaneous temperature such that, by measuring gradients in the temperature distribution over skin surfaces, one may be able to diagnose or quantify the progression of vascular conditions in whose pathogenesis a reduction in subcutaneous blood perfusion plays a critical role (e.g. peripheral artery disease). As proof of principle, this study investigates the local changes in the skin temperature of healthy humans (15 male, [Formula: see text] years old, BMI [Formula: see text] kg/m 2) undergoing two physical challenges designed to vary their haemodynamic status. Skin temperature was measured in four central regions (forehead, neck, chest, and left shoulder) and four peripheral regions (left upper arm, forearm, wrist, and hand) using an infrared thermal camera. We compare inter-region patterns. Median temperature over the peripheral regions decreased from baseline after both challenges (maximum decrease: [Formula: see text] °C at 60 s after exercise; [Formula: see text] and [Formula: see text] °C at 180 s of cold-water immersion; [Formula: see text]). Median temperature over the central regions showed no significant changes. Our results show that the non-contact measurement of perfusion-related changes in peripheral temperature from infrared video data is feasible. Further research will be directed towards the thermographic study of patients with symptomatic peripheral vascular disease.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: