A Noise-Reduced Light-to-Frequency Converter for Sub-0.1% Perfusion Index Blood SpO[Formula: see text] Sensing
Abstract:
To improve the SpO 2 sensing system performance for hypoperfusion (low perfusion index) applications, this paper proposes a low-noise light-to-frequency converter scheme from two aspects. First, a low-noise photocurrent buffer is proposed by reducing the amplifier noise floor with a transconductance-boost ( gm-boost) circuit structure. Second, a digital processing unit of pulse-frequency-duty-cycle modulation is proposed to minimize the quantization noise in the following timer by limiting the maximum output frequency. The proposed light-to-frequency sensor chip is designed and fabricated with a 0.35- μm CMOS process. The overall chip area is 1 × 0.9 mm 2 and the typical total current consumption is about 1.8 mA from a 3.3-V power supply at room temperature. The measurement results prove the proposed functionality of output pulse duty cycle modulation, while the SNR of a typical 10-kHz output frequency is 59 dB with about 9-dB improvement when compared with the previous design. Among them, 2-3 dB SNR improvement stems from the gm-boosting and the rest comes from the layout design. In-system experimental results show that the minimum measurable PI using the proposed blood SpO 2 sensor could be as low as 0.06% with 2-percentage-point error of SpO 2. The proposed chip is suitable for portable low-power high-performance blood oximeter devices especially for hypoperfusion applications.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.