Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
The effect of contralateral disease on carotid Doppler frequency
A C Hayes1, K W Johnston, W H Baker
1Department of Surgery, Loyola University Medical Center, Maywood, IL 60153.
Abstract:
Continuous-wave Doppler frequency analysis is one standard of noninvasive evaluation for stenotic carotid disease. Interpretation is most commonly based on frequency recorded at the site of stenosis. If flow velocity is increased because of contralateral disease, this criterion may overstate the degree of stenosis. To investigate this, three centers contributed 167 patients to a study of carotid Doppler frequency analysis. Each patient underwent bilateral carotid studies by a standard protocol with use of continuous-wave 5 MHz Doppler probe. There were 309 patent and 25 occluded internal carotids seen on subsequent angiographs. Each patient side was categorized by the severity of ipsilateral disease (less than 45%, 45% to 70%, 71% to 99%, occlusion) and then subgrouped by contralateral disease. For all carotid arteries, the optimal peak frequency to detect 45% or more stenosis was 5500 Hz, with an overall accuracy of 92.2%. Within the three classifications of ipsilateral stenosis, a trend was noted that related increasing peak frequency to greater degrees of contralateral disease. This was most apparent when the contralateral internal carotid artery was occluded. Of all false-positive errors, 43% were accounted for by this subset that represented 15% of the total population. For the 25 patients with occlusion opposite a stenosis, the 5500 Hz cutoff of Doppler peak frequency yielded only 76% accuracy; an ROC curve showed that a cutoff value of 8500 Hz improved overall accuracy to 92% for these patients. By applying two cutoff criteria--5500 Hz for those with patent contralateral internal carotids and 8500 Hz for those in whom a contralateral Doppler signal was not detected--the overall accuracy for all patients improved to 93.3%. It is concluded that contralateral occlusion affects Doppler peak frequency by increasing the velocity in the companion carotid artery, whereas severe contralateral stenosis did not result in a consistent pattern of increased velocity.
More Related Videos
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation