Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
Published on: April 7, 2023
The Evaluation of Upper Airway Complications Secondary to Intubation: Cuff Pressure Manometer Versus Conventional
Özlem Ünsal1, Nurullah Seyhun1, Bilge Türk1
1Department of Otolaryngological, Şişli Etfal Training and Research Hospital, İstanbul, Turkey.
Objectives:
General anesthesia is preferred in most otorhinolaryngologic surgeries. The aim of the present study was to evaluate upper airway complications secondary to intubation including sore throat, cough, dysphonia, and dysphagia considering endotracheal tube (ET) cuff pressure, tube diameter, and duration of intubation.
Methods:
After the assignment of 67 patients to the study and control groups, ET cuff pressure was adjusted to be between 20 and 30 cm H2O using a cuff pressure manometer in the study group. In the control group, the cuff pressure was decided by the anesthesiologist using the conventional palpation method. Sore throat, cough, dysphonia, and dysphagia were compared between the groups at 4, 8, and 24 h postoperatively.
Results:
Cuff pressure was significantly higher in the control group than in the study group. In the control group, sore throat was more frequently observed at 4, 8, and 24 h, whereas in the study group, cough and dysphonia were more often observed at 4 and 8 h. At 4 and 8 h, cough was found to be related to the duration of intubation.
Conclusion:
Arrangement of cuff pressure using a cuff manometer is suggested to decrease complications of the upper airway secondary to intubation because of the higher rate of these complaints in patients whose cuff pressure is arranged by the conventional palpation method.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Pre-Procedural Guidelines for Assessing Blood Pressure