Related Experiment Video
Updated: Dec 12, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Optimizing Testing for BPPV - The Loaded Dix-Hallpike
Luke Andera1, William James Azeredo1, Joseph Scott Greene1
1Department of Otolaryngology Head and Neck Surgery, Geisinger Medical Center, Pennsylvania, USA.
Objectives:
Although the Dix-Hallpike testing is generally considered as the gold standard for the identification of the posterior canal benign paroxysmal positional vertigo (BPPV), we investigated a modification of the maneuver termed the "loaded Dix-Hallpike."
Study Design:
Prospective randomized controlled trial.
Materials And Methods:
Twenty-eight patients participated in this prospective study comparing the standard Dix-Hallpike (S-DH) to the loaded Dix-Hallpike (L-DH) test. Each patient underwent repeated testing with the S-DH and the L-DH. The patients were placed into two groups. Fourteen patients underwent 3 rounds of S-DH testing followed by 3 rounds of L-DH testing. The other fourteen patients underwent 3 rounds of L-DH testing followed by 3 rounds of S-DH testing. The duration of nystagmus and the latency prior to the onset of nystagmus were measured for each test. Additionally, the patients were asked to rate the severity of their symptoms following each test.
Results:
The duration of nystagmus of the L-DH was significantly longer than that of the S-DH (p<0.0001). The patients reported a higher severity score with L-DH as compared to with S-DH (p<0.001). The L-DH was found to be more sensitive than the S-DH (p=0.0131).
Conclusion:
The L-DH produces significantly longer duration of nystagmus, stronger symptoms, and improved sensitivity when compared to the S-DH.