Combined versus subtraction-only technique in parathyroid scintigraphy: effect on scan interpretation
Mugisha J Sebikali1, James M Warwick1, Alex G Doruyter2
1Division of Nuclear Medicine, Stellenbosch University and Tygerberg Hospital.
Introduction:
Parathyroidectomy is the choice of treatment for patients with primary and tertiary hyperparathyroidism. Scintigraphic, preoperative localization of hyperfunctioning parathyroid tissue depends on either a delayed washout technique, a subtraction technique, or a combination of the two. The rationale for adopting a combination approach is its presumed superior sensitivity, but there is limited evidence to support this strategy at the cost of patient inconvenience and impact on departmental workflows.
Objective:
To determine whether a combined technique detects any additional lesions during scan interpretation compared to using subtraction-only technique in patients undergoing parathyroid scintigraphy before surgery.
Methods:
A retrospective analysis was performed of parathyroid scans at Tygerberg Hospital between January 2012 and April 2018. Scans were reinterpreted by consensus by three readers, blinded to the original interpretation. A McNemar discordant pairs analysis was then performed.
Results:
A total of 97 participant scans were reviewed (female: 71; mean age: 50.8 years). The number of patients with primary, secondary, and tertiary hyperparathyroidism were 63, 21, and 13, respectively. A total of 192 lesions were identified in this study. While both combined and subtraction-only approaches identified hyperfunctioning parathyroid lesions, only four lesions were identified using the combined technique that were missed by the subtraction technique. This result was not statistically significant (P = 0.125).
Conclusion:
Based on our findings, the combined parathyroid scintigraphic technique does not improve lesion detection and may be dispensed with. Doing so will enhance patient convenience and comfort and improve departmental workflows without compromising lesion detection.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT