Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Pulse Oximeter Plethysmograph Variation During Hemorrhage in Beta-Blocker-Treated Swine
Yoon Sun Jung1, Woo Sang Cho2, Gil Joon Suh3
1Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Background:
Beta-blockers blunt the stress response to hemorrhage. Our aim was to investigate the feasibility of noninvasive pulse oximeter plethysmographic waveform variation (PoPV) for predicting blood volume loss in an esmolol-treated swine hemorrhagic shock model.
Materials And Methods:
Controlled hemorrhage was induced in eight male domestic pigs. In four pigs, a total of 15% and 30% blood volume was drawn step-by-step over 10 min in each step (controlled hemorrhage-only pigs). In the other four pigs, the heart rate (HR) was reduced and maintained by 30% from baseline by esmolol infusion before controlled hemorrhage (esmolol-treated pigs). Diagnostic abilities of HR, pulse pressure variation (PPV), PoPV, and mean arterial pressure for 15% and 30% blood volume loss were determined by the area under the receiver operating characteristic curve (AUC).
Results:
PoPV was well correlated with PPV in controlled hemorrhage-only pigs (r = 0.717) and esmolol-treated pigs (r = 0.532). In controlled hemorrhage-only pigs, HR (AUC = 0.841 and 0.864), PPV (0.878 and 0.843), and PoPV (0.779 and 0.793) accurately predicted 15% and 30% of blood volume loss. In esmolol-treated pigs, the diagnostic ability of HR was decreased (AUC = 0.766 and 0.733). However, diagnostic abilities of PPV (0.848 and 0.804) and PoPV (0.808 and 0.842) were not deteriorated.
Conclusions:
The diagnostic ability of HR for blood volume loss was blunted by esmolol. However, those of PPV and PoPV were not altered. PoPV may be considered to be a useful noninvasive tool to predict blood volume loss in injured patients taking beta-blockers.
Related Concept Videos
Measurement of Blood Pressure
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.