Related Experiment Video
Updated: Dec 11, 2025

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Extubation Failure and Major Adverse Events Secondary to Extubation Failure Following Neonatal Cardiac Surgery
Shinya Miura1, Peter V Jardim1,2, Warwick Butt1,2,3
1Paediatric Intensive Care Unit, The Royal Children's Hospital, Parkville, VIC, Australia.
Objectives:
To describe the prevalence and consequences of major adverse events secondary to extubation failure after neonatal cardiac surgery.
Design:
A single-center cohort study.
Setting:
A medical-surgical, 30-bed PICU in Victoria, Australia.
Patients:
One thousand one hundred eighty-eight neonates less than or equal to 28 days old who underwent cardiac surgery from January 2007 to December 2018.
Interventions:
None.
Measurements And Main Results:
Extubation failure was defined as unplanned reintubation within 72 hours after a planned extubation. Major adverse event was defined as one or more of cardiac arrest, emergency chest reopening, extracorporeal membrane oxygenation, or death within 72 hours after extubation. One hundred fifteen of 1,188 (9.7%) neonates had extubation failure. Hospital mortality was 17.4% and 2.0% in neonates with and without extubation failure. Major adverse event occurred in 12 of 115 reintubated neonates (10.4%). major adverse event included cardiac arrest (n = 10), chest reopening (n = 8), extracorporeal membrane oxygenation (n = 5), and death (n = 0). Cardiovascular compromise accounted for major adverse event in eight: ventricular dysfunction (n = 3), pulmonary overcirculation (n = 2), coronary ischemia (n = 2), cardiac tamponade (n = 1). In a multivariable logistic regression, factors associated with major adverse event were high complexity in cardiac surgery (odds ratio 5.9; 95% CI: 1.1-32.2) and airway anomaly (odds ratio 6.0; 95% CI: 1.1-32.6). Hospital morality was 25% and 17% in reintubated neonates with and without major adverse event.
Conclusions:
Around 10% of reintubated neonates suffered major adverse event within 72 hours of extubation. Neonates suffering major adverse event had high mortality. Major adverse event should be monitored and reported in future studies of extubation failure. Along with tracking of extubation failure rates, major adverse event secondary to extubation failure may also serve as a key performance indicator for ICUs and registries.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...

