A step forward in the equivalence between thermal and differential-flow modulated comprehensive two-dimensional gas
Federico Stilo1, Elena Gabetti1, Carlo Bicchi1
1Università degli Studi di Torino Turin, Italy.
Abstract:
Comprehensive two-dimensional gas chromatography (GC×GC) based on flow-modulation (FM) is gaining increasing attention as an alternative to thermal modulation (TM), the recognized GC×GC benchmark, thanks to its lower operational cost and rugged performance. An accessible, rational procedure to perform method translation between the two platforms would be highly valuable to facilitate compatibility and consequently extend the flexibility and applicability of GC×GC. To enable an effective transfer, the methodology needs to ensure preservation of the elution pattern, separation power, and sensitivity. Here, a loop-type thermal modulation system with dual detection (TM-GC×GC-MS/FID) used for the targeted analysis of allergens in fragrances is selected as reference method. Initially, six different columns configurations are systematically evaluated for the flow-modulated counterpart. The set-up providing the most consistent chromatographic separation (20 m x 0.18 mm dc x 0.18 μm df + 1.8 m x 0.18 mm dc x 0.18 μm df) is further evaluated to assess its overall performance in terms of sensitivity, linearity, accuracy, and pattern reliability. The experimental results convincingly show that the method translation procedure is effective and allows successful transfer of the target template metadata. Additionally, the FM-GC×GC-MS/FID system is suitable for challenging applications such as the quantitative profiling of complex fragrance materials.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...