Related Experiment Video
Updated: Dec 11, 2025

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
A selective comprehensive reversed-phase×reversed-phase 2D-liquid chromatography approach with multiple complementary
Ryan Karongo1, Tohru Ikegami2, Dwight R Stoll3
1Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-) Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
Abstract:
There is a huge, still increasing market for synthetic and therapeutic peptides. Their quality control is commonly based on a generic reversed-phase liquid chromatography (RPLC) method with C18 stationary phase and acetonitrile gradient with 0.1% trifluoroacetic acid in the mobile phase. It performs exceptionally well for a wide variety of impurities, yet structurally closely related impurities with similar sequences, not resolved in preparative RPLC, may easily coelute in the corresponding QC run as well. To address this problem an advanced generic 2D-LC impurity profiling method was developed in this work. It employs a selective comprehensive (high resolution sampling) RP×RP 2D-LC separation using a 100×2.1 mm ID column with the common acidic generic gradient in the first dimension, while RPLC under basic pH on a short 30×3 mm ID column is used in the second dimension. Recording data with a UV detector at 215 nm after 1D separation provides the common generic 1D chromatogram. However, after the 2D separation a flow splitter enabled recording of the signals of complementary detectors comprising a diode array detector (DAD) in-line with a charged aerosol detector (CAD) and a quadrupole-time-of-flight (QTOF) mass spectrometer (MS) with an electrospray ionization (ESI) source. Generic conditions of this 2D-LC method have been established through optimization of 2D stationary and mobile phase considering different pH values and buffer concentrations. The orthogonal separation principle has been documented by a number of therapeutic peptides including Exenatide, Octreotide, Cyclosporine A and Oxytocin as well as some other proprietary synthetic peptides. The information density can be further enhanced by using the QTOF-MS detector by data independent acquisition with SWATH. Through this sequential window acquisition of all theoretical fragment ion mass spectra it became possible to collect MS/MS data comprehensively in the high-resolution sampling window, thus enabling the extraction of 2D-EICs from fragment ions and the generation of 2D-contour plots of all product ions. Using Oxytocin as an example for an important therapeutic peptide, the ability of this advanced generic sRP-UV×RP-DAD-CAD-ESI-QTOF-MS/MS method with SWATH for peptide quality control is discussed.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
08:232 in 1: One-step Affinity Purification for the Parallel Analysis of Protein-Protein and Protein-Metabolite Complexes
Published on: August 6, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Instrumentation