On Outage Probability and Ergodic Rate of Downlink Multi-User Relay Systems with Combination of NOMA, SWIPT, and

Ta Chi Hieu1, Nguyen Le Cuong2, Tran Manh Hoang3

  • 1Faculty of Radio-Electronic Engineering, Le Quy Don Technical University, 236 Hoang Quoc Viet, Hanoi 100000, Vietnam.

Related Concept Videos

Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
408
Beams with Symmetric Loadings01:15

Beams with Symmetric Loadings

The moment-area method is an analytical tool used in structural engineering to determine the slope and deflection of beams under various loads. Consider a cantilever with a concentrated load and moment at the free end. The first step is constructing a free-body diagram to calculate the reactions at the fixed end. Next, the bending moment diagram is plotted to visualize how the bending moment varies along the beam's length, focusing on points where the bending moment equals zero.
The M/EI...
334
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
706
Propagation Speed of Electromagnetic Waves01:30

Propagation Speed of Electromagnetic Waves

Electromagnetic waves are consistent with Ampere's law. Assuming there is no conduction current Ampere's law is given as:
4.4K
Beams with Unsymmetric Loadings01:17

Beams with Unsymmetric Loadings

Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
316
Poisson Probability Distribution01:09

Poisson Probability Distribution

A Poisson probability distribution is a discrete probability distribution. It gives the probability of a number of events occurring in a fixed interval of time or space if these events happen at a known average rate and independently of the time since the last event. For example, a book editor might be interested in the number of words spelled incorrectly in a particular book. It might be that, on average, there are five words spelled incorrectly in 100 pages. The interval is 100 pages.
The...