A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Delivery room ultrasound study to assess heart rate in newborns: DELIROUS study
S Bobillo-Perez1,2, M Balaguer2, I Jordan2
1Disorders of Immunity and Respiration of the Paediatric Critical Patient Research Group, Institut Recerca Hospital Sant Joan de Déu, Universitat de Barcelona, Barcelona, Spain.
During neonatal resuscitation in the delivery room, heart rate guides clinical intervention, and although different methods have been evaluated as auscultation, pulse oximetry, and electrocardiography, they have various limitations. This was a prospective observational study which aim was to evaluate the accuracy and speed of ultrasound for measuring neonatal heart rate compared with stethoscope, pulse oximetry, and electrocardiography. Simultaneous determinations of heart rate using stethoscope, ultrasound, pulse oximetry, and electrocardiography were performed. Fifty term newborns were included. There were no differences according to the turn on time of the ultrasound, pulse oximetry, and electrocardiography (p = 0.666), but the placement time and the detection time from birth were shorter for ultrasound (p < 0.001). A stronger positive correlation was detected between ultrasound and electrocardiography at 90 (Rho = 0.926), and 120 s (Rho = 0.920) with p < 0.001. The Bland-Altman analysis showed a bias of - 2.23 (p = 0.129) between ultrasound and electrocardiography at 90 s, and a bias of 0.44 (p = 0.092) at 120 s. Instead, the bias between auscultation and electrocardiography at 90 s was - 6.71 (p = 0.131), and at 120 s was of - 4.67 (p = 0.793).Conclusions: Ultrasound is a fast method to detect heart rate in the delivery room and has a good correlation with stethoscope and electrocardiography. What is Known: • During neonatal resuscitation in the delivery room, heart rate guides clinical intervention, and although different methods have been evaluated, they have various limitations. What is New: • Heart rate ultrasound is a good and fast method to detect HR in the delivery room with a good correlation with electrocardiography and stethoscope.
During neonatal resuscitation in the delivery room, heart rate guides clinical intervention, and although different methods have been evaluated as auscultation, pulse oximetry, and electrocardiography, they have various limitations. This was a prospective observational study which aim was to evaluate the accuracy and speed of ultrasound for measuring neonatal heart rate compared with stethoscope, pulse oximetry, and electrocardiography. Simultaneous determinations of heart rate using stethoscope, ultrasound, pulse oximetry, and electrocardiography were performed. Fifty term newborns were included. There were no differences according to the turn on time of the ultrasound, pulse oximetry, and electrocardiography (p = 0.666), but the placement time and the detection time from birth were shorter for ultrasound (p < 0.001). A stronger positive correlation was detected between ultrasound and electrocardiography at 90 (Rho = 0.926), and 120 s (Rho = 0.920) with p < 0.001. The Bland-Altman analysis showed a bias of - 2.23 (p = 0.129) between ultrasound and electrocardiography at 90 s, and a bias of 0.44 (p = 0.092) at 120 s. Instead, the bias between auscultation and electrocardiography at 90 s was - 6.71 (p = 0.131), and at 120 s was of - 4.67 (p = 0.793).Conclusions: Ultrasound is a fast method to detect heart rate in the delivery room and has a good correlation with stethoscope and electrocardiography. What is Known: • During neonatal resuscitation in the delivery room, heart rate guides clinical intervention, and although different methods have been evaluated, they have various limitations. What is New: • Heart rate ultrasound is a good and fast method to detect HR in the delivery room with a good correlation with electrocardiography and stethoscope.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Ultrasonography
During an ultrasonography procedure, a handheld device called...