Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Building a stable and accurate model for heavy metal detection in mulberry leaves based on a proposed analysis
Liang Yang1, Liuwei Meng2, Huaqi Gao1
1College of Animal Sciences, Zhejiang University, Hangzhou 310058, PR China.
Abstract:
Laser-induced breakdown spectroscopy (LIBS) was used to rapidly detect heavy metals in mulberry leaves. For the purpose of increasing detection stability and accuracy, a novel analysis framework consisting of a Kohonen self-organizing map (SOM), a variable selection method using the successive projection algorithm (SPA) and uninformative variable elimination (UVE), and a consensus modeling strategy was proposed for processing LIBS data to determine copper (Cu) and chromium (Cr) content. Results showed that the best regression model for Cu and Cr content achieved the residual predictive deviation (RPD) values of 10.0494 and 8.3874, respectively, and root mean square error of prediction (RMSEP) values of 110.4550 and 41.4561, respectively. The proposed strategy provides a high-accuracy and rapid alternative to the traditional method for monitoring heavy metals in mulberry leaves, which could guarantee the quality of mulberry leaves and potentially be used in food-related industries.