Related Experiment Video
Updated: Dec 11, 2025

A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
The Potential Role of Smart Infusion Devices in Preventing or Contributing to Medication Administration Errors: A
Yogini H Jani, Gillian M Chumbley1, Dominic Furniss2
1Imperial College Healthcare NHS Trust, Pain Management Centre, Charing Cross Hospital, London, United Kingdom.
Objectives:
Errors in medication administration are common, with many interventions suggested to reduce them. For intravenous infusion-related errors, "smart infusion devices" incorporating dose error reduction software are widely advocated. Our aim was to explore the role of smart infusion devices in preventing or contributing to medication administration errors using retrospective review of 2 complementary data sets that collectively included a wide range of errors with different levels of actual or potential harm.
Methods:
We reviewed 216 medication administration errors identified from an observational study in clinical practice and 123 medication incidents involving infusion devices reported to a national reporting system. The impact of smart infusion devices in preventing or contributing to these errors was assessed by the research team and an expert panel.
Results:
The data suggest that use of any infusion device rather than gravitational administration may have prevented 13% of observed errors and 8% of reported incidents; additional reductions may be possible with standalone smart infusion devices, and further potential reductions with smart infusion devices integrated with electronic prescribing and barcode administration systems. An estimated 52% to 73% of errors that occurred with traditional infusion pumps could be prevented with such integrated smart infusion devices. In the few cases where smart infusion devices were used, these contributed to errors in 2 of 58 observed errors and 7 of 8 reported incidents.
Conclusions:
Smart infusion devices not only prevent some medication administration errors but can also contribute to them. Further evaluation of such systems is required to make recommendations for policy and practice.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Guidelines for Nursing Documentation I
Factual:
The following points emphasize the significance of upholding accurate and unbiased documentation in healthcare.
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...