Use of Crystal Violet to Improve Visual Cytopathic Effect-based Reading for Viral Titration using TCID50 Assays
Published on: February 12, 2022
14.3K
A Comparative Analysis of Methods for Titering Reovirus
Yi-Chen Yang1, Xian-Yao Wang1,2, Yuan-Yuan An1,2
1Stem Cell and Tissue Engineering Research Center, Guizhou Medical University, Guiyang 550004, China
Pharmaceutical Nanotechnology
|August 28, 2020
Summary
A new standard curve method using real-time unlabeled cell analysis (RTCA) accurately measures reovirus titers, offering a faster alternative to traditional methods. This technique, along with tunable resistance pulse detection (TRPS), provides efficient tools for assessing viral virulence.
Area of Science:
- Virology
- Cell Biology
- Biotechnology
Background:
- Accurate measurement of virus titers is crucial for understanding viral amplification and virulence.
- Traditional methods like the median tissue culture infectious dose (TCID50) are time-consuming and labor-intensive.
- There is a need for simpler, more convenient, and rapid methods for quantifying virus titers.
Purpose of the Study:
- To establish a standard curve correlating real-time unlabeled cell analysis (RTCA) half-cell index time (CIT50) with virus titer.
- To evaluate the feasibility and application value of RTCA and tunable resistance pulse detection (TRPS) technologies for virus titer measurement.
- To compare the performance of RTCA and TRPS against the traditional TCID50 method.
Main Methods:
- L929 cells were cultured to determine optimal inoculation density.
- RTCA was employed to analyze half-cell index (CI50) values of reovirus-infected L929 cells.
- A CIT50-TCID50 standard curve and regression equation were developed; RTCA, TCID50, and TRPS methods were used for reovirus titer detection.
Main Results:
- Optimal L929 cell propagation occurred at an initial density of 6 × 103 cells/well.
- A linear correlation (R2 = 0.9742) was found between CIT50 and TCID50: y = -2.1806x + 71.023.
- Virus titers obtained were 7×10^9.6821 pfu/mL (RTCA), 4.52×10^10 pfu/mL (TRPS), and 7×10^9.467 pfu/mL (TCID50).
Conclusions:
- The RTCA-based CIT50-TCID50 standard curve method provides a quantitative and rapid means for reovirus titer detection using L929 cells.
- RTCA offers high sensitivity and accuracy with reduced assay time compared to the TCID50 method.
- TRPS technology is faster for virus quantification but shows lower precision than RTCA and TCID50.