Related Experiment Video
Updated: Dec 10, 2025

Gene Expression Analysis of Endothelial Cells Exposed to Shear Stress Using Multiple Parallel-plate Flow Chambers
Published on: October 21, 2018
Side-dependent effect in the response of valve endothelial cells to bidirectional shear stress
Emilie Faure1, Eric Bertrand2, Amélie Gasté1
1Aix Marseille Univ, INSERM, Marseille Medical Genetics, U1251, 13005 Marseille, France.
Abstract:
Endothelial cells covering the aortic and ventricular sides of the aortic valve leaflets are exposed to different stresses, in particular wall shear stress (WSS). Biomechanical stimuli actively regulate valve tissue structure and induce remodeling events leading to valve dysfunction. Endothelial to mesenchymal transformation (EndMT), for example, has been associated with aortic valve disease. The biomechanical response of cells at different sides of the leaflets has not been clearly characterized. To analyze the mechanical response of valve endothelial cells (VECs) we developed a unique fluid activation device that applies physiologically relevant pulsatile WSS. We characterized the morphology and function of adult porcine aortic VECs derived from the opposite sides of aortic valve leaflets following exposure to different pulsatile WSS. We found that elongation and orientation of cells in response to pulsatile WSS depends on their side of origin. Quantification of gene expression confirms phenotypic differences between aortic and ventricular VECs. Aortic VECs exposed to pulsatile WSS similar to that in vivo at the tip of aortic side of the valve leaflet upregulated pro-EndMT (ACTA2, Snail, TGFβ1) and inflammation (ICAM-1, VCAM-1) genes, whereas expression of endothelial markers like PECAM-1 was decreased. Conversely, ventricular-VECs showed strong increase of PECAM-1 expression and no activation of pro-EndMT marker. Finally, we found that stress-induced genes are upregulated in both cell types, at higher levels in ventricular compared to aortic VECs. Application of physiological shear stress levels using a fluid activation device therefore reveals functional differences in VECs derived from opposite sides of the aortic valve leaflets.
More Related Videos
07:17Electrophysiological Recordings of Single-cell Ion Currents Under Well-defined Shear Stress
Published on: August 2, 2019
09:20The Assembly and Application of 'Shear Rings': A Novel Endothelial Model for Orbital, Unidirectional and Periodic Fluid Flow and Shear Stress
Published on: October 31, 2016