Selection of calibration compounds for selectivity evaluation of wall-coated, open-tubular columns for gas
1Department of Chemistry, Rm 185 Chemistry, Wayne State University, Detroit, MI 48202, USA.
Abstract:
To facilitate faster selectivity evaluation of wall-coated, open-tubular columns using the solvation parameter model a reduced set of calibration compounds is identified and validated for the temperature ranges 60-140 °C and 160-260 °C. The Kennard-Stone uniform mapping algorithm is used to identify the calibration compounds from a larger database of compounds with known retention properties previously adopted for column selectivity evaluation. Thirty-five compounds for each temperature range are required to minimize the standard deviation of the system constants used for selectivity evaluation and to minimize differences between system constants determined by conventional calibration and the reduced calibration compounds. The models for the reduced calibration compounds on ten siloxane-based and poly(ethylene glycol) stationary phases have a coefficient of determination of 0.984 to 0.998 and standard error of the estimate of 0.012 to 0.30. The predictive capability of models is evaluated for the reduced sets of calibration compounds using external test sets with ranking of the calibration models by changes in the average error, average absolute error and root mean square error of prediction for the test sets. For the selected thirty-five reduced calibration compounds the range for the average absolute error was 0.014 to 0.033 and 0.016 to 0.040 for the root mean square error of prediction for the independent test sets.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Principles Of Column Chromatography