Related Experiment Video
Updated: Dec 10, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Effect of vessel wall segmentation on volumetric and radiomic parameters of coronary plaques with adverse
Márton Kolossváry1, Natasa Jávorszky1, Júlia Karády2
1MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68 Városmajor Street, Budapest, Hungary.
Background:
Quantitative coronary plaque parameters are increasingly being utilized as surrogate endpoints of pharmaceutical trials. However, little is known whether differences in segmentation significantly alter parameter values.
Methods:
Overall, 100 coronary plaques with adverse imaging characteristics were segmented automatically, by two experts (R1-R2) and three nonexperts (R3-R5). Low attenuation noncalcified (LANCP), noncalcified and calcified plaque volume were calculated and 4310 radiomic features were extracted. Intraclass correlation coefficient (ICC) values were calculated between the segmentations.
Results:
ICC values between expert readers were 0.84 [CI: 0.77-0.89] for total; 0.83 [CI: 0.76-0.88] for noncalcified; 0.96 [CI: 0.94-0.98] for calcified and 0.65 [CI: 0.51-0.75] for LANCP volumes. Comparing nonexperts' and experts' results, ICC ranged between 0.64 and 0.90 for total; 0.63-0.91 for noncalcified; 0.86-0.96 for calcified and 0.34-0.84 for LANCP volume. All readers (R1-R5) showed poor agreement with automatic segmentation (range: 0.00-0.27), except for calcified plaque volumes (range: 0.73-0.88). Regarding radiomic features, expert readers (R1-R2) achieved good reproducibility (ICC>0.80) in 88.6% (39/44) of first-order, 62.0% (424/684) of gray level co-occurrence matrix (GLCM), 75.8% (50/66) of gray level run length matrix (GLRLM) and 19.8% (696/3516) of geometrical parameters. Between experts and nonexperts, ICC ranged between: 70.5%-86.4% for first-order, 31.0%-58.3% for GLCM, 24.2%-78.8% for GLRLM and 6.2%-21.1% for geometrical features, while between all readers and automatic segmentation ICC ranged between: 25.0%-38.6%; 0.0%-0.0%; 0.0%-3.0% and 1.1%-1.4%, respectively.
Conclusions:
Even among experts there is a considerable amount of disagreement in LANCP volumes. Nevertheless, expert readers have the best agreement which currently cannot be replaced with nonexperts' or automatic segmentation.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024