Related Experiment Video
Updated: Dec 10, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Sources of outlier data in the bioanalytical and clinical part of a piroxicam bioequivalence study
Objective:
This paper analyzes the potential outliers in the bioanalytical and clinical part of a bioequivalence study, the effect on bioequivalence decisions whether or not it is appropriate to eliminate them from the statistical evaluation of bioequivalence.
Materials And Methods:
The clinical part was a cross-over, two periods, two sequences bioequivalence study concerning two piroxicam formulations, on healthy subjects. A simulation study evaluated the influence of 10% errors on the percent bias of calculated concentrations from nominal ones.
Results:
In bioequivalence studies, it is not possible to distinguish between relevant types of outliers based only on statistical criteria. The "problem" is particularly acute when the omission of outliers leads to a bias in the decision concerning bioequivalence from rejection to acceptance. In such cases, there is the suspicion of subjective analysis and torture of data. The effect of analytical errors at high plasma levels was criticized for the calculated concentrations in the neighborhood of lower limit of quantification. Errors at low concentrations have a less significant effect. In the pharmacokinetic analysis, several types of outliers were shown: single points, curves, pairs of curves corresponding to the same subject, intrasubject ratios of areas under curves and maximum concentrations. These pharmacokinetic outliers could have had, at the same time, bioanalytical, physiological and physicochemical causes.
Conclusion:
Considering the results, it was proposed the following algorithm in the analysis of outlier data and outlier subjects in bioequivalence studies: evaluation of the implications of the decision concerning elimination of outliers on the decision concerning bioequivalence; application of the statistic tests for detection of outliers data; evaluations from the point of view of physiological pharmacokinetics, final decision concerning elimination of outliers.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
12:22The Use of Reverse Phase Protein Arrays RPPA to Explore Protein Expression Variation within Individual Renal Cell Cancers
Published on: January 22, 2013
Related Concept Videos
Bioequivalence Data: Statistical Interpretation
Bioequivalence studies: Biowaivers
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Bioavailability Study Design: Absolute Versus Relative Bioavailability
Analysis of Population Pharmacokinetic Data
Bioavailability Study Design: Healthy Subjects Versus Patients