Utilizing functional lumen imaging probe in directing treatment for post-fundoplication dysphagia
Salih Samo1, Ramzi Mulki1, Marie L Godiers1
1Division of Digestive Diseases, Department of Medicine, Emory University School of Medicine, 1525 Clifton Rd NE, Atlanta, GA, 30322, USA.
Background:
Esophagogastric junction obstruction (EGJO) post-fundoplication (PF) is difficult to identify with currently available tests. We aimed to assess the diagnostic accuracy of EGJ opening on functional lumen imaging probe (FLIP) and dilation outcome in FLIP-detected EGJO in PF dysphagia.
Methods:
We prospectively collected data on PF patients referred to Esophageal Clinic over 18 months. EGJO diagnosis was made by (a) endoscopist's description of a narrow EGJ/wrap area, (b) appearance of wrap obstruction or contrast/tablet retention on esophagram, or (c) EGJ-distensibility index (DI) < 2.8 mm2/mmHg on real-time FLIP. In patients with EGJO and dysphagia, EGJ dilation was performed to 20 mm, 30 mm, or 35 mm in a stepwise fashion. Outcome was assessed as % dysphagia improvement during phone call or on brief esophageal dysphagia questionnaire (BEDQ) score.
Results:
Twenty-six patients were included, of whom 17 (65%) had a low EGJ-DI. No patients had a hiatal hernia greater than 3 cm. Dysphagia was the primary symptom in 17/26 (65%). In 85% (κ = 0.677) of cases, EGJ assessment (tight vs. open) was congruent between the combination of endoscopy (n = 26) and esophagram (n = 21) vs. EGJ-DI (n = 26) on FLIP. Follow-up data were available in 11 patients who had dilation based on a low EGJ-DI (4 with 20 mm balloon and 7 with ≥ 30 mm balloon). Overall, the mean % improvement in dysphagia was 60% (95% CI 37.7-82.3%, p = 0.0001). Nine out of 11 patients, including 6 out of 7 undergoing pneumatic dilation, had improvement ≥ 50% in dysphagia (mean % improvement 72.2%; 95% CI 56.1-88.4%, p = 0.0001).
Conclusions And Inferences:
Functional lumen imaging probe is an accurate modality for evaluating for EGJ obstruction PF. FLIP may be used to select patients who may benefit from larger diameter dilation.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy