Related Experiment Video
Updated: Dec 10, 2025

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Distinguishing Isomeric Aromatic Radical Cations by Using Energy-Resolved Ion Trap and Medium Energy
Mark Romanczyk1, Yuyang Zhang1, Mckay Easton1,2
1Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States.
Abstract:
Different collision-activated dissociation (CAD) methods were evaluated for their effectiveness at distinguishing several ionized isomeric aromatic compounds by using a linear quadrupole ion trap/orbitrap mass spectrometer. The compounds were ionized by using atmospheric pressure chemical ionization (APCI) with carbon disulfide solvent in the positive ion mode to generate stable molecular ions with limited fragmentation. They were subjected to CAD in the linear quadrupole ion trap (ITCAD) and in an octupole collision cell (medium-energy collision-activated dissociation, MCAD; also known as HCD). Experiments conducted by attempting to vary ion activation times revealed that MCAD and ITCAD occur in the microsecond and millisecond time regimes, respectively. MCAD was found to impart substantially greater internal energies into the molecular ions compared to ITCAD. Accordingly, molecular ions subjected to MCAD favored dissociation via fast σ-bond cleavages, while molecular ions subjected to ITCAD tended to favor rearrangement reactions. MCAD used in the energy-resolved mode (ER-MCAD) enabled the distinction of six ionized isomeric compounds from each other based on modified crossing-point energies (collision energies where the molecular ions and selected fragment ions have an equal abundance). This was not true for ER-ITCAD. Overall, MCAD was superior over ITCAD at the differentiation of isomeric ions, and it provided more detailed structural information.
Related Concept Videos
Mass Spectrometry: Aromatic Compound Fragmentation
High-Resolution Mass Spectrometry (HRMS)
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the...
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...