Time response enhancement for variable speed drive systems by using five-level cascade four quadrant chopper in
Safwan Nadweh1, Ola Khaddam1, Ghassan Hayek1
1Electrical Power Engineering, Tishreen University, Lattakia, Syria.
Abstract:
This research introduces a filtering circuit design integrated with the DC-link of a medium power variable speed drive (VSD) system. The designed filtering circuit employs modern power electronic circuits to improve time response characteristics in both grid and dc-link sides. Depending on the widely used multi-level converters, a conventional three-level H-bridge four-quadrant chopper scheme was developed into a cascade five-level H-bridge four-quadrant chopper scheme. The time response of the proposed system was performed with both choppers, and results showed that voltage drop on cascade chopper transistors was reduced to half in comparison with voltage drop on conventional four-quadrant chopper transistors. Moreover, the sharp fluctuations in system's waves were mitigated; consequently, time response characteristics in both steady and transient states were remarkably improved. The total harmonic distortion factor THD% of the input current and voltage was reduced to 26.2% and 2.43% respectively and the ripple factor RF for DC-link current was reduced to 0.196.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Phase-lead and Phase-lag Controllers
Fast Decoupled and DC Powerflow
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...