A Simplified Numerical Approach to Examine the Sensitivity of Two-Electrode Capacitance Sensor Orientation to Capture
Fayez M Al-Alweet1,2, Artur J Jaworski3, Yusif A Alghamdi4,5
1National Center for Oil and Gas Technology, King Abdulaziz City for Science and Technology, P.O. Box 6086, Riyadh 11442, Saudi Arabia.
Abstract:
This work involved the simulation of both a multiphase gas-liquid flow and the electromagnetic field representing a two-electrode capacitance sensor in a circular pipe. The simulation investigates in particular the sensitivity of the sensor orientation around the pipe (i.e., top-to-bottom or side-to-side) that best capture the induced flow patterns. The presented numerical work is a simplified simulation by COMSOL multi-physics which was validated by a systematic and an extensive experimental work, using (a) a specially designed simple capacitance sensor (i.e., concave two electrodes), (b) different gas-liquid superficial velocity combinations, (c) different flow section inclinations, and (d) high-speed camera images. The numerical modelling capacitance values were validated against the experimentally measured values which shows a satisfactory level of agreement with a deviation of less than ±2%. The quantity of finite points was between 280,000 and 340,000, which was influenced by the simulated flow pattern. The simulated cases captured the generated flow patterns and their variation inside the pipe, which was in a good agreement when compared to the experimental work as time-dependent values. It was found that the best orientation for the utilized two-electrode capacitance sensor was the top-to-bottom configuration. This is because the sensor's electrical field distribution was more sensitive, and capable of detecting a greater range of capacitance values. The sensitivity of the top-to-bottom configuration was 1.25-1.64 times greater than that of the side-to-side configuration. Therefore, for design purposes and performance optimization, it is recommended to use the top-to-bottom configuration.
More Related Videos
11:08Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue
Published on: September 5, 2015
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving
Potentiometry: Membrane Electrodes
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...