Related Experiment Video
Updated: Dec 9, 2025

Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
Assessment of a Personal Interactive Carbon Monoxide Breath Sensor in People Who Smoke Cigarettes: Single-Arm Cohort
Jennifer D Marler1, Craig A Fujii1, Kristine S Wong1
1Carrot Inc., Redwood City, CA, United States.
Background:
Tobacco use is the leading cause of preventable morbidity and mortality. Existing evidence-based treatments are underutilized and have seen little recent innovation. The success of personal biofeedback interventions in other disease states portends a similar opportunity in smoking cessation. The Pivot Breath Sensor is a personal interactive FDA-cleared (over-the-counter) device that measures carbon monoxide (CO) in exhaled breath, enabling users to link their smoking behavior and CO values, and track their progress in reducing or quitting smoking.
Objective:
The objective of this study is to assess the Pivot Breath Sensor in people who smoke cigarettes, evaluating changes in attitudes toward quitting smoking, changes in smoking behavior, and use experience.
Methods:
US adults (18-80 years of age, ≥10 cigarettes per day [CPD]) were recruited online for this remote 12-week study. Participants completed a screening call, informed consent, and baseline questionnaire, and then were mailed their sensor. Participants were asked to submit 4 or more breath samples per day and complete questionnaires at 1-4, 8, and 12 weeks. Outcomes included attitudes toward quitting smoking (Stage of Change, success to quit, and perceived difficulty of quitting), smoking behavior (quit attempts, CPD reduction, and 7-, 30-day point prevalence abstinence [PPA]), and use experience (impact and learning).
Results:
Participants comprised 234 smokers, mean age 39.9 (SD 11.3) years, 52.6% (123/234) female, mean CPD 20.3 (SD 8.0). The 4- and 12-week questionnaires were completed by 92.3% (216/234) and 91.9% (215/234) of participants, respectively. Concerning attitude outcomes, at baseline, 15.4% (36/234) were seriously thinking of quitting in the next 30 days, increasing to 38.9% (84/216) at 4 weeks and 47.9% (103/215) at 12 weeks (both P<.001). At 12 weeks, motivation to quit was increased in 39.1% (84/215), unchanged in 54.9% (118/215), and decreased in 6.0% (13/215; P<.001). Additional attitudes toward quitting improved from baseline to 12 weeks: success to quit 3.3 versus 5.0 (P<.001) and difficulty of quitting 2.8 versus 4.3 (P<.001). Regarding smoking behavior, at 4 weeks, 28.2% (66/234) had made 1 or more quit attempts (≥1 day of abstinence), increasing to 48.3% (113/234) at 12 weeks. At 4 weeks, 23.1% (54/234) had reduced CPD by 50% or more, increasing to 38.5% (90/234) at 12 weeks. At 12 weeks, CPD decreased by 41.1% from baseline (P<.001), and 7- and 30-day PPA were 12.0% (28/234) and 6.0% (14/234), respectively. Concerning use experience, 75.3% (171/227) reported the sensor increased their motivation to quit. More than 90% (>196/214) indicated the sensor taught them about their CO levels and smoking behavior, and 73.1% (166/227) reported that seeing their CO values made them want to quit smoking.
Conclusions:
Use of the Pivot Breath Sensor resulted in a significant increase in motivation to quit, a reduction in CPD, and favorable quit attempt rates. These outcomes confer increased likelihood of quitting smoking. Accordingly, the results support a role for biofeedback via personal CO breath sampling in smoking cessation.
Trial Registration:
ClinicalTrials.gov NCT04133064; https://clinicaltrials.gov/ct2/show/NCT04133064.
More Related Videos
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: