Development, diagnostic performance, and interobserver agreement of a 18F-flurpiridaz PET automated perfusion
René R Sevag Packard1, C David Cooke2,3, Kenneth F Van Train3
1Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA, USA. rpackard@mednet.ucla.edu.
Background:
Computerized methodologies standardize the myocardial perfusion imaging (MPI) interpretation process.
Methods:
To develop an automated relative perfusion quantitation approach for 18F-flurpiridaz, PET MPI studies from all phase III trial participants of 18F-flurpiridaz were divided into 3 groups. Count distributions were obtained in N = 40 normal patients undergoing pharmacological or exercise stress. Then, N = 90 additional studies were selected in a derivation group. Following receiver operating characteristic curve analysis, various standard deviations below the mean normal were used as cutoffs for significant CAD, and interobserver variability determined. Finally, diagnostic performance was compared between blinded visual readers and blinded derivations of automated relative quantitation in the remaining N = 548 validation patients.
Results:
Both approaches yielded comparable accuracies for the detection of global CAD, reaching 71% and 72% by visual reads, and 72% and 68% by automated relative quantitation, when using CAD ≥ 70% or ≥ 50% stenosis for significance, respectively. Similar results were observed when analyzing individual coronary territories. In both pharmacological and exercise stress, automated relative quantitation demonstrated significantly more interobserver agreement than visual reads.
Conclusions:
Our automated method of 18F-flurpiridaz relative perfusion analysis provides a quantitative, objective, and highly reproducible assessment of PET MPI in normal and CAD subjects undergoing either pharmacological or exercise stress.
More Related Videos
09:58Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)