Naked Eye Chemosensing of Anions by Schiff Bases

Hafiz Muhammad Junaid1, Madeeha Batool1, Farah Wahida Harun2

  • 1Institute of Chemistry, University of the Punjab, Lahore, Pakistan.

Related Concept Videos

Amines to Sulfonamides: The Hinsberg Test01:23

Amines to Sulfonamides: The Hinsberg Test

The Hinsberg test is a method to identify primary, secondary and tertiary amines, named after its pioneer, Oscar Hinsberg. Here, amines are treated with benzenesulfonyl chloride, also known as the Hinsberg reagent, in the presence of an excess of aqueous base, followed by acidification. Based on the nature of the amines, different changes are observed.
Generally, a primary amine reacts with the Hinsberg reagent to produce an N-substituted benzenesulfonamide. The electron-withdrawing sulfonyl...
4.2K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
3.5K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.4K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
525