Rate Dependent Krasnoselskii-Pokrovskii Modeling and Inverse Compensation Control of Piezoceramic Actuated Stages
Wenjun Li1, Linlin Nie2, Ying Liu2
1College of Transportation, Jilin University, Changchun 130022, China.
Abstract:
The piezoceramic actuated stages have rate-dependent hysteresis nonlinearity, which is not simply related to the current and historical input, but also related to the frequency of the input signal, seriously affects its positioning accuracy. Consider the influence of frequency on hysteresis modeling, a rate-dependent hysteresis nonlinearity model that is based on Krasnoselskii-Pokrovskii (KP) operator is proposed in this paper. A hybrid optimization algorithm of improved particle swarm optimization and cuckoo search is employed in order to identify the density function of rate-dependent KP model, avoiding the blind search process caused by the high randomness of Levy's flight in the cuckoo search algorithm, and improving the parameter identification performance. For the sake of eliminating the hysteresis characteristics, an inverse feed-forward compensation control that is based on recursive method is proposed without any additional conditions, and a feed-forward compensation controller is designed accordingly. The experimental results show that, under different frequency input signals, as compared with the classic KP model, the proposed rate-dependent KP model can accurately describe the rate-dependent hysteresis characteristics of the piezoceramic actuated stages, and the recursive inverse feed-forward compensation control method can effectively mitigate the hysteresis behaviors.
More Related Videos
07:40Manufacturing, Control, and Performance Evaluation of a Gecko-Inspired Soft Robot
Published on: June 10, 2020
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
PI Controller: Design
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...