Related Experiment Video
Updated: Dec 9, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Creatinine clearance after cimetidine administration in a new short procedure: comparison with plasma and renal
Thomas Stehlé1,2, Khalil El Karoui1,2, Mehdi Sakka3
1Assistance Publique des Hôpitaux de Paris (AP-HP), Groupe Hospitalier Henri-Mondor/Albert Chenevier, Service de Néphrologie et Transplantation, Creteil, France.
Background:
Creatinine clearance after cimetidine administration (Cim-CreatClr) was once proposed as a method of glomerular filtration rate (GFR) measurement, but has been largely abandoned. We investigated whether a new short procedure for Cim-CreatClr determination could be considered an appropriate method for GFR measurement.
Methods:
A 150-min protocol involving oral cimetidine administration was developed to determine Cim-CreatClr. In total, 168 patients underwent simultaneous assessments of creatinine clearance before and after cimetidine administration [basal creatinine clearance (Basal-CreatClr) and Cim-CreatClr, respectively], renal iohexol clearance and plasma iohexol clearance (R-iohexClr and P-iohexClr, respectively). We compared the agreement between the various methods of GFR measurement, using Bland-Altman plots to determine biases, precisions (standard deviation of the biases) and accuracy (proportions of GFR values falling within 10, 15 and 30% of the mean: P10, P15 and P30, respectively).
Results:
After cimetidine administration, Basal-CreatClr decreased by 19.8% [95% reference limits of agreement (95% LoA): -2.2 to 41.7%]. The bias between Cim-CreatClr and P-iohexClr was -0.6% (95% LoA -26.8 to 28%); the precision was 14.0%; P10, P15 and P30 were 57.1% [95% confidence interval (95% CI) 49.3 to 64.7%], 73.2% (95% CI 65.8 to 79.7%) and 97.0% (95% CI 93.2 to 99.0%), respectively. Due to the positive bias (16.7%; 95% LoA -3.6 to 36.9%) of Cim-CreatClr relative to R-iohexClr, accuracy of Cim-CreatClr relative to R-iohexClr was poor despite a good precision (10.3%).
Conclusions:
Our study shows a high level of agreement between Cim-CreatClr and P-iohexClr. These results suggest that this short Cim-CreatClr procedure is a valid method for GFR measurement, which might be useful, in particular, in situations in which P-iohexClr is not suitable or not available.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
One-Compartment Open Model: Urinary Excretion Data and Determination of k

