Related Experiment Video
Updated: Dec 9, 2025

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
Discrepancies in Electrolyte Measurements by Direct and Indirect Ion Selective Electrodes due to Interferences by
Parul Chopra1, Sudip Kumar Datta2
1Department of Hematology and Immunology, Dr. Lal PathLabs, New Delhi, India.
Abstract:
Objectives We aim to report the simultaneous effect of different protein and lipid concentrations on sodium (Na + ) and potassium (K + ) measurement by direct and indirect ion selective electrodes (dISE and iISE) in patient samples. Materials and Methods Na + and K + were measured in 195 serum samples received in the laboratory using iISE by Roche Modular P800 autoanalyzer and using dISE by XI-921 ver. 6.0 Caretium electrolyte analyzer. Serum total protein (TP), cholesterol (Chol), and triglycerides (TG) were measured using conventional photometric methods on Roche Modular P800 autoanalyzer. Differences for each pair of results for Na + (Diff_Na + = [Na + dISE- Na + iISE ]) and K + (Diff_K + = [K + dISE- K + iISE ]) were calculated. Patient subgroups with high, normal, or low TP (< 5, 5-7.9, or ≥ 8 g/dL), Chol (< 150, 150-299, or ≥300 mg/dL), or TG (< 150, 150-299, or ≥300 mg/dL) were compared using analysis of variance. Note that 95% confidence interval of Diff_Na + and Diff_K + were calculated to see the number of samples showing clinically significant differences. Results Diff_Na + ( p = 0.007) and Diff_K + ( p = 0.002) were found significant between samples with normal and high TP. However, effect of TG was not significant. Chol concentration affected Diff_Na + significantly between low versus normal ( p = 0.002), and high versus normal ( p = 0.031) Chol groups. Diff_K + was significant ( p = 0.009) between low versus normal Chol. Clinically relevant disagreement of ≥|5| mmol/L for Na + was observed in high percentage of samples including all subcategories; however, for K + only 3.6% of the total samples showed disagreement of ≥ |0.5| mmol/L. A multivariate regression equation based on fit regression model was also derived. Conclusion Summarily, interchangeable use of electrolyte results from dISE and iISE is not advisable, especially in a setting of hyperproteinemia (≥8 g/dL) or hypercholesterolemia (≥300 mg/dL); more so for Na + .
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Ion-Exchange Chromatography
Potentiometry: Membrane Electrodes
EDTA: Indirect and Alkalimetric Titration
Interfacial Electrochemical Methods: Overview
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...

