Study of the Influence of Winding and Sensor Design on Ultra-High Frequency Partial Discharge Signals in Power
Chandra Prakash Beura1, Michael Beltle1, Stefan Tenbohlen1
1Institute of Power Transmission and High Voltage Technology (IEH), University of Stuttgart, 70569 Stuttgart, Germany.
Abstract:
Ultra-high frequency (UHF) partial discharge (PD) measurements in power transformers are becoming popular because of the advantages of the method. Therefore, it is necessary to improve the basic understanding of the propagation of signals inside the transformer tank and the factors that influence the sensitivity of the measurement. Since the winding represents a major obstacle to the propagation of the UHF signals, it is necessary to study the effect of winding design on signal propagation. Previous research activities have studied these effects using simplified models, and it is essential to consider the complexity of propagation in a complete transformer tank. Additionally, the quality of UHF PD measurements depends, to a large extent, on the sensitivity of the UHF sensors. In this contribution, a simulation model consisting of a simple, grounded enclosure with multiple winding designs is used to study the propagation characteristics of UHF signals when an artificial PD source is placed inside the winding. After analysis of the results, the winding designs are incorporated in an existing and validated simulation model of a 420 kV power transformer and analyzed to observe the influence in a more complex structure. Two commonly used sensor designs are also used in the simulation model to receive the signals. In all cases, the propagation and signal characteristics are analyzed and compared to determine the influence of the winding and sensor design on the UHF signals. It is found that the level of detail of winding design has a significant impact on the propagation characteristics. However, the attenuation characteristics of the UHF signals received by the two sensor designs are similar, with the electric field distribution around the sensor being the key difference.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential...