Automatic unsupervised respiratory analysis of infant respiratory inductance plethysmography signals
Carlos A Robles-Rubio1, Robert E Kearney1, Gianluca Bertolizio2
1Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada.
Abstract:
Infants are at risk for potentially life-threatening postoperative apnea (POA). We developed an Automated Unsupervised Respiratory Event Analysis (AUREA) to classify breathing patterns obtained with dual belt respiratory inductance plethysmography and a reference using Expectation Maximization (EM). This work describes AUREA and evaluates its performance. AUREA computes six metrics and inputs them into a series of four binary k-means classifiers. Breathing patterns were characterized by normalized variance, nonperiodic power, instantaneous frequency and phase. Signals were classified sample by sample into one of 5 patterns: pause (PAU), movement (MVT), synchronous (SYB) and asynchronous (ASB) breathing, and unknown (UNK). MVT and UNK were combined as UNKNOWN. Twenty-one preprocessed records obtained from infants at risk for POA were analyzed. Performance was evaluated with a confusion matrix, overall accuracy, and pattern specific precision, recall, and F-score. Segments of identical patterns were evaluated for fragmentation and pattern matching with the EM reference. PAU exhibited very low normalized variance. MVT had high normalized nonperiodic power and low frequency. SYB and ASB had a median frequency of respectively, 0.76Hz and 0.71Hz, and a mode for phase of 4o and 100o. Overall accuracy was 0.80. AUREA confused patterns most often with UNKNOWN (25.5%). The pattern specific F-score was highest for SYB (0.88) and lowest for PAU (0.60). PAU had high precision (0.78) and low recall (0.49). Fragmentation was evident in pattern events <2s. In 75% of the EM pattern events >2s, 50% of the samples classified by AUREA had identical patterns. Frequency and phase for SYB and ASB were consistent with published values for synchronous and asynchronous breathing in infants. The low normalized variance in PAU, was consistent with published scoring rules for pediatric apnea. These findings support the use of AUREA to classify breathing patterns and warrant a future evaluation of clinically relevant respiratory events.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...