Ultrasound-guided lung lavage for life-threatening bronchial obstruction due to meconium plug
Valentina Dell'Orto1, Roberta Centorrino1, Daniele De Luca1
1Division of Paediatrics and Neonatal Critical Care, Medical Center "A. Béclère", Paris Saclay University Hospitals, APHP, Paris, France.
Abstract:
We present a case of life-threatening airway obstruction caused by meconium aspiration, a condition with significant neonatal mortality and morbidity. Lung ultrasound detected the obstruction and helped in the clinical management allowing to perform a quick and selective bronchoalveolar lavage with diluted surfactant.
More Related Videos
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
09:58A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Pneumothorax-II
Clinical Manifestations: